The Cuffed Endotracheal Tube Oral Preformed from HENAN AILE INDUSTRIAL CO., LTD delivers enterprise-grade performance backed by real manufacturing excellence. Engineered in our 12,000 m² facility with Class 100,000 cleanrooms and supported by 7 national patents, this specialized device combines kink-resistant design with high-volume low-pressure (HVLP) cuff technology.
Our generation capacity of 300,000 units per month guarantees steady supply for your healthcare institution. Each tube experiences 100% sleeve astuteness testing and meets ISO 13485, CE, and FDA measures. With thermosensitive DEHP-free PVC development and a preformed anatomical bend, you get reliable surgical field clearance and prevalent tracheal assurance in each procedure.
The item understands basic challenges in verbal intubation amid head and neck surgeries. Not at all like straight tubes, the preformed South-facing twist coordinates the breathing circuit connector absent from the surgical site.
This plan avoids coincidental extubation and dispenses with obstructions amid maxillofacial, ENT, and verbal strategies. You can center on the operation whereas the tube keeps up a secure, obvious airway.
The HVLP sleeve conveys fixing weight equally over a bigger tracheal surface region. This minimizes mucosal ischemia chance whereas avoiding goal of verbal discharges amid common anesthesia.

| Parameter | Details |
|---|---|
| Product Name | Endotracheal Tube Oral Preformed |
| Material | Thermosensitive, DEHP-free PVC |
| Cuff Type | High-Volume Low-Pressure (HVLP) |
| Design Curve | South-facing preformed bend |
| Safety Features | Murphy Eye, radiopaque line, 15mm universal connector |
| Sterilization | EO (Ethylene Oxide) sterilized |
| Packaging | Individually packed by blister pouch |
| Certifications | CE / ISO 13485 / FDA approved |
| Minimum Order | 100 PCS |
| Supply Capacity | 300,000 units/month |
| Private Label | OEM/ODM services available |
During orthognathic surgery or complex dental extractions, your surgical field needs to remain clear. The Cuffed Endotracheal Tube Oral Preformed routes the ventilator circuit over the patient's chin, giving you unobstructed access to the mouth.
The kink-resistant plan anticipates tube compression from surgical retractors. You keep up reliable ventilation without repositioning concerns.
Tonsillectomies, thyroidectomies, and laryngeal surgeries request exactness. The preformed twist keeps the breathing circuit absent from the sterile field whereas keeping up aviation route stability.
You decrease the chance of defilement and surgical intrusion. The smooth, adjusted distal tip guarantees atraumatic addition indeed in challenging anatomy.
For patients requiring delayed verbal intubation, the preformed shape decreases weight on the lips and teeth. This minimizes the hazard of weight bruises at the corners of the mouth compared to straight tubes.
Your ICU group can perform verbal cleanliness and aviation route care more successfully. The thermosensitive PVC adjusts to the patient's anatomical forms after inclusion, lessening mechanical irritation.

Kink Resistance Technology
The pre-shaped anatomical curve significantly reduces tube kinking at the bend point. Even when the patient's head position changes, you maintain consistent airflow throughout the procedure.
Advanced HVLP Cuff System
Our high-volume low-pressure cuff provides an effective seal at recommended pressures of 20-30 cmH₂O. This protects tracheal blood flow while preventing aspiration.
Thermosensitive Material
The medical-grade PVC is firm enough for easy intubation but softens at body temperature. It conforms naturally to your patient's respiratory tract, reducing trauma and improving comfort.
Atraumatic Insertion Design
The smooth, rounded distal tip and integrated Murphy Eye prevent tissue damage during placement. You can intubate confidently even in patients with sensitive airways.
Every Cuffed Endotracheal Tube Oral Preformed from Aile Industrial undergoes rigorous testing before reaching your facility:
Cuff Integrity Testing: 100% of tubes complete a 24-hour inflation test to verify zero leakage at clinical pressure levels per ISO 5361 standards.
Kink Resistance Verification: We test each tube's ability to maintain a patent lumen when bent at its preformed angle at 37°C.
Connector Security: Pull-tests ensure the 15mm universal connector remains securely attached under high tension during patient transport and positioning.
Biocompatibility Assurance: Comprehensive testing per ISO 10993 includes cytotoxicity, sensitization, and intracutaneous reactivity evaluations.
Visual Inspection Protocol: Both automated systems and manual checks verify burr-free Murphy Eyes and perfectly smooth distal tips.
Our Class 100,000 cleanrooms and strict process controls ensure product consistency. You receive the same reliable performance in every unit.
At HENAN AILE INDUSTRIAL CO., LTD, we don't just manufacture medical devices—we build solutions that support your clinical excellence. Since 2014, our group has centered on coordination fabric science with real-world healthcare challenges.
Our 12,000 m² office combines progressed generation capabilities with nonstop development. We offer proficient specialized preparing, 24-hour quick reaction benefit, and full-lifecycle bolster for your supply chain.
Whether you require reliable bulk supply or customized OEM/ODM arrangements, our experienced group is prepared to back your necessities.

Q: Why is the preformed bend beneficial compared to a standard tube?
A: The preformed bend reduces the risk of kinking and minimizes pressure on the patient's lips. It provides better surgical access by directing the breathing circuit away from the operative field.
Q: What is the recommended cuff pressure for the product?
A: Maintain pressure between 20-30 cmH₂O to prevent aspiration while protecting tracheal blood flow. Regular monitoring with a cuff manometer is essential.
Q: Can these tubes be used in MRI environments?
A: Yes, provided the pilot balloon spring is made of non-ferromagnetic materials. Always check the specific manufacturer labeling before MRI use.
Q: Are these tubes reusable?
A: No, they are strictly single-use devices, EO sterilized to prevent cross-contamination. Never attempt to re-sterilize or reuse.
Q: How do I choose between a 'North' and 'South' preformed tube?
A: Oral preformed tubes are typically South-facing, curving toward the chin. North-facing tubes are generally designed for nasal intubation and curve toward the forehead.
Ready to enhance your IV therapy protocols with the Cuffed Endotracheal Tube Oral Preformed? Reach us at admin@aileindus.com – Let's work together to deliver better patient care.