uncuffed tracheostomy tube

Manufacturer: AVACARE Brand
Category: Class II
Order MOQ: 1,000 Pieces
Classification: Grade: Medical Grade
Sample Provision: Provided upon request
OEM/ODM Service: OEM/ODM accepted
Product Description

Uncuffed Tracheostomy Tube – Medical-Grade Airway Solution by HENAN AILE INDUSTRIAL

Manufactured by HENAN AILE INDUSTRIAL CO., LTD since 2014, each tube is produced in our 12,000 m² facility with Class 100,000 cleanrooms under ISO 13485 and CE/FDA certifications. Available in four precise sizes—70mm, 75mm, 80mm, and 85mm—our uncuffed tracheostomy tube is crafted from premium medical-grade PVC or silicone.

With 7 national licenses backing our development, you get a straightforward tube body for simple emission observing, secure settled wings that fit comfortably around the neck, and ethylene oxide sterilization guaranteeing single-use security. Idealize for patients transitioning off ventilators or requiring discourse treatment, this tube permits common wind current to the upper aviation route whereas keeping up a obvious tracheal channel.

What Makes Our Uncuffed Tracheostomy Tube Different?

Superior Fabric Science

You advantage from medical-grade materials built for security. Our thermosensitive PVC relaxes at body temperature, adjusting delicately to your patient's life systems. For expanded situation scenarios, the silicone variation offers uncommon biocompatibility with zero latex or DEHP content.

The straightforward development lets you screen emissions at a look. This visual clarity diminishes pointless suctioning methods and makes a difference you make quicker clinical decisions.

Precision Building for All Age Groups

We plan each measure with correct ID and OD proportions to minimize wind current resistance. Our tubes highlight a all inclusive 15mm connector compliant with ISO 5356-1, so you can consistently join HMEs, talking valves, or ventilator circuits.

The coordinates radiopaque line guarantees precise X-ray situating post-insertion. You'll know precisely where the tube sits without guesswork.

Safety-First Obsession System

Displacement is a genuine concern amid understanding exchanges or repositioning. That's why our settled wing plan embraces the neck form safely. Combined with the included flexible strap, you get steady arrangement that diminishes the hazard of coincidental decannulation.

Each item arrives exclusively bundled and EO-sterilized, disposing of cross-contamination stresses right out of the box.

Technical Specifications

Parameter Details
Tube Sizes 70mm, 75mm, 80mm, 85mm (without cuff)
Material Medical-grade PVC / Silicone
Connector 15mm ISO 5356-1 universal
Sterilization Ethylene Oxide (EO)
Packaging Individual sterile pack / 1,000 PCS per carton
Classification Class II Medical Device
Standards ISO 13485, CE, FDA
MOQ 1,000 pieces
Radiopaque Line Integrated for X-ray visibility
OEM/ODM Available upon request

Core Applications You Can Trust

Pediatric and Neonatal Airway Management

Children's aviation routes display special challenges. The cricoid cartilage acts as the normal anatomical seal in youthful patients, making cuffed tubes pointless and possibly hurtful. Our uncuffed plan anticipates mucosal injury whereas keeping up a secure airway.

You'll discover this tube perfect for pediatric ICUs, neonatal units, and post-surgical recuperation rooms where sensitive tissue security is paramount.

Long-Term Rehabilitation and Home Care

Patients with chronic obstructive conditions or neuromuscular disorders often need ongoing airway support without mechanical ventilation. The uncuffed tracheostomy tube allows them to use speaking valves like the Passy Muir Valve, dramatically improving quality of life.

Home caregivers appreciate the straightforward maintenance routine. Families can manage pulmonary hygiene confidently, knowing the tube is designed for extended wear—up to 29–90 days depending on secretion levels.

Decannulation Weaning Protocols

Transitioning patients off tracheostomy requires careful assessment. Moving to an uncuffed tube lets you evaluate whether your patient can breathe around the device and clear secretions independently.

This staged approach reduces risks during the decannulation process. You gain valuable data about respiratory drive and airway patency before complete tube removal.

company exhibition

Why Healthcare Professionals Choose HENAN AILE INDUSTRIAL

Manufacturing Excellence

Our 12,000 m² cutting edge generation office isn't fair big—it's shrewd. Course 100,000 cleanrooms guarantee contamination-free generation, whereas strict prepare controls keep up consistency over each batch.

You get the same dependable execution whether you arrange 1,000 pieces or 100,000. Our steady supply capacity implies you never confront startling deficiencies amid basic care periods.

Innovation Supported by Patents

With 7 national licenses, we persistently refine our item plans based on genuine clinical criticism. Our R&D group combines fabric science mastery with hands-on healthcare involvement, making arrangements that address real bedside challenges.

Full-Lifecycle Support

Your organization with us doesn't conclusion at conveyance. We give proficient specialized preparing for your staff, 24-hour quick reaction benefit, and continuous item interview. Require offer assistance with supply chain coordination? Our group is continuously one e-mail away.

AILE factory

​​​​​​​​​​​​​​

FAQ

Q:Can the item be utilized with mechanical ventilation?

A:Generally, no. The nonappearance of a sleeve permits noteworthy discuss spillage, making it troublesome to keep up PEEP and steady tidal volumes. In any case, in particular pediatric "leak-speech" scenarios or suddenly breathing patients, it may be suitable beneath near clinical supervision.

Q:How does this tube encourage speech?

A:Air bypasses the tube amid close, streaming through the vocal ropes when combined with a one-way talking valve. This reestablishes near-normal phonation, making a difference patients communicate and take part more effectively in their recovery.

Q:What are the dangers with dysphagia patients?

A:Without a sleeve to piece subglottic discharges, there's an lifted desire chance. You ought to evaluate gulping work carefully and consider extra goal safeguards like dietary alterations or situating strategies.

Q:How regularly ought to I supplant the tube?

A:Replacement interims shift by convention and discharge burden. Medical-grade silicone forms regularly final 29–90 days. Screen for discoloration, hull buildup, or auxiliary changes that flag prior substitution is needed.

Q:Is the internal cannula essential?

A:For grown-up patients, yes—it's profoundly prescribed. The inward cannula anticipates tube impediment from dried bodily fluid without requiring a full tube alter. Whereas pediatric sizes may overlook this include, grown-ups advantage essentially from this included security layer.

Q:Can I customize sizes or branding?

A:Absolutely. We offer OEM/ODM administrations to meet your particular prerequisites. Whether you require interesting measuring, custom bundling, or branded items, our group can oblige your needs with a 1,000-piece least arrange.

product transportation

Contact Us

Our uncuffed tracheostomy tube provides the safety, reliability, and performance your patients deserve. Contact us today at admin@aileindus.com to request samples, discuss customization options, or place your order.