Combined Spinal Epidural Needles - Premium Medical Solution for Advanced Regional Anesthesia 

HENAN AILE INDUSTRIAL CO., LTD brings you our AVACARE Brand Combined Spinal Epidural Needles, engineered in our 12,000 m² facility equipped with Class 100,000 cleanrooms. This professional-grade kit integrates precision manufacturing with clinical excellence, featuring medical-grade PVC and stainless steel construction in configurations of (15G-18G)×(80/90)MM.

Our product holds CE and ISO13485 certifications, backed by 7 national patents and strict quality control. With a minimum order of 5,000 pieces, we offer custom labeling services and sample availability. Each needle features our precision Tuohy curve tip design, exceptional tactile feedback for the "loss of resistance" technique, and clear graduation markings for accurate depth monitoring during procedures.

Understanding the CSE Needle System

The products represent a sophisticated medical device that revolutionizes regional anesthesia through the "needle-through-needle" technique. You get the rapid onset of spinal anesthesia combined with the flexibility of epidural analgesia—all from a single puncture site.

This dual-functionality approach addresses your biggest clinical challenges. It eliminates the high failure rate of standalone epidural blocks. It extends the limited duration of single-shot spinal anesthesia. Most importantly, it minimizes patient trauma by requiring only one insertion point.

Healthcare professionals worldwide trust this method as the gold standard for obstetric analgesia and major lower-limb surgeries. You can establish immediate surgical conditions while maintaining comprehensive postoperative pain management.

Technical Specifications of Combined Spinal Epidural Needles

Parameter Details
Model Number (15G-18G)×(80/90)MM
Material Medical Grade PVC + Stainless Steel
Instrument Classification Class III
Brand AVACARE Brand
Certifications CE & ISO13485
Packing Blister/Carton
Packaging Options Individual or with injection needles
Sterilization EO (Ethylene Oxide)
MOQ 5,000 Pieces
Private Label Available
Sample Service Yes

Key Product Features

Precision Tuohy Curve Design

Your victory depends on exact needle situation. Our interestingly bended tip avoids the catheter absent from the dura mater, drastically diminishing inadvertent dural cut hazard. This back-eye plan makes a committed exit harbour for the spinal needle, avoiding sliding and guaranteeing steady subarachnoid space entry.

Superior Tactile Response

You need reliable feedback during procedures. Our needles are engineered specifically for the "loss of resistance" technique, delivering distinct tactile sensitivity as you enter the epidural space. This enhanced feedback helps you work with confidence and precision.

Clear Depth Monitoring

Safety requires accurate measurements. High-contrast graduation markings along the needle shaft let you monitor insertion depth in real-time. These precise indicators help you maintain optimal positioning throughout the procedure.

Medical-Grade Construction

We construct each needle from premium 304/316L stainless steel, providing the tensile strength and flexibility you need. The transparent polycarbonate hub ensures clear CSF visualization, while the pencil point design minimizes dural trauma and reduces Post-Dural Puncture Headache risks.

Clinical Applications

Obstetric Analgesia

When you're managing labor and delivery, Combined Spinal Epidural Needles provide immediate pain relief during active labor. The spinal component works instantly, while the epidural catheter allows dose titration throughout prolonged delivery or emergency cesarean sections. This is your solution for comprehensive "painless childbirth" programs.

Joint Replacement Surgery

Total hip and knee arthroplasty demand reliable anesthesia solutions. The CSE technique delivers a dense motor block for surgical precision. You can then use the epidural pathway for continuous postoperative infusion, promoting early patient mobilization and faster recovery.

Major Abdominal and Pelvic Procedures

High-stress surgical situations require flexible torment administration. The spinal component addresses prompt surgical boost, whereas the epidural component oversees complex fiery reactions after surgery. You'll decrease systemic opioid necessities and move forward quiet results.

Manufacturing Excellence

Our production facility demonstrates our commitment to quality. Operating from a modern 12,000-square-meter space, we maintain Class 100,000 cleanroom standards throughout manufacturing. Strict process controls ensure every product delivers consistent reliability.

Aile factory

Our experienced R&D team focuses on integrating material science with real clinical applications. We've earned 7 national patents through continuous innovation. Every products kit reflects our decade of expertise since our founding in 2014.

Quality assurance extends from raw materials to finished products. Our ISO 13485 certified quality management system, along with CE and FDA certifications, confirms our compliance with international medical industry standards.

company exhibition

Safety and Compliance

Patient safety drives everything we do. Our needles comply with ISO 7864 standards for sterile hypodermic needles. We've incorporated ISO 80369-6 (NRFit) connectors to prevent dangerous misconnections between neuraxial and intravenous lines.

Each kit undergoes rigorous quality control testing. We subject needles to extreme bending angles to verify structural integrity. Stiffness and breakage resistance tests ensure the spinal needle maintains performance during the needle-through-needle technique.

Remember, these are single-use only devices. EO sterilization prevents cross-contamination and guarantees your patient's safety. Never reuse these needles under any circumstances.

FAQ

Q: What makes the Tuohy curve design superior for epidural placement?

A: The curved tip with back-eye design provides a controlled exit path for the spinal needle. This reduces needle skidding and ensures consistent angle entry into the subarachnoid space, improving your first-attempt success rate significantly.

Q: How do NRFit connectors enhance patient safety?

A: NRFit (ISO 80369-6) connectors are specifically designed for neuraxial applications. They physically prevent accidental connection between neuraxial and intravenous lines—a critical safety feature that eliminates potentially fatal administration errors.

Q: Can I control how far the spinal needle extends?

A: Absolutely. Our kits feature graduated markings on the spinal needle showing exact extension beyond the epidural needle tip. Quality designs include locking mechanisms for precise depth control, typically extending 10-15mm beyond the Tuohy tip.

Q: Do pencil point needles really reduce headache complications?

A: Clinical evidence confirms that pencil point tips (Whitacre or Sprotte designs) part dural fibers rather than cutting them. This results in faster dural hole closure compared to Quincke-type tips, significantly reducing Post-Dural Puncture Headache incidence.

Q: What structural testing ensures needle reliability?

A: We conduct comprehensive "stiffness and resistance to breakage" testing. Each needle undergoes extreme bending angle tests according to industry standards. This verifies structural integrity and ensures the needle won't break during the needle-through-needle technique.

Q: Are these needles suitable for reprocessing and reuse?

A: No. The products are strictly single-use only devices. Each kit is sterilized with EO gas and must be discarded after one procedure to prevent cross-contamination and ensure optimal patient safety.

Q: What payment and ordering options do you offer?

A: We accept L/C and T/T payment methods. Our minimum order quantity is 5,000 pieces. We provide sample availability for evaluation and offer custom labeling services to meet your branding requirements.

Q: How quickly can you fulfill orders?

A: Our efficient production management and stable supply capacity ensure reliable delivery schedules. We maintain strict process control to guarantee product consistency. Contact us to discuss your specific timeline requirements and global delivery options.

product transportation

Contact Us

Ready to enhance your anesthesia program with premium Combined Spinal Epidural Needles? Our team provides 24-hour rapid response service, technical training, and complete supply chain support.

Email us today: admin@aileindus.com