Manufactured in our 12,000 m² facility with Class 100,000 cleanrooms, this 60 Drops/mL IV Infusion Set without Air Vent, 150cm Tube micro-drip infusion set calibrates exactly 60 drops to equal 1.0 ml. The 150cm medical-grade tubing gives ideal reach for seriously care units and neonatal hatcheries. Its non-vented spike plan works consistently with collapsible plastic packs, keeping up a closed-system environment that disposes of airborne defilement risks.
Backed by ISO 13485 and CE certifications, additionally 7 national licenses in restorative advancement, you get reliable drop arrangement precision inside ±5-10% resilience, guaranteeing secure pharmaceutical titration in pediatric, oncology, and basic care applications.
You need accuracy when every drop counts. Our set features a specialized dropper mechanism that maintains the 60 drops/mL calibration throughout extended infusions.
The transparent drip chamber lets you monitor flow rates visually. You can quickly verify drop speed and adjust the smooth roller clamp for precise control.
The non-vented spike addresses your contamination concerns directly. When paired with flexible infusion bags, the container collapses naturally as it empties.
No air vent means no pathway for airborne pathogens. You maintain fluid sterility from bag to patient, crucial for chemotherapy and immunocompromised patients.
This design also prevents over-hydration risks in sensitive populations. You control the infusion environment completely.
The 150cm tube length solves your workspace challenges. You can position IV poles at comfortable distances from incubators, stretchers, or ICU beds.
The medical-grade tubing resists kinking even when routed around equipment. Your infusions continue uninterrupted, reducing nursing intervention time.
DEHP-free material options are available for neonatal applications where plasticizer exposure is a concern.
Every component meets biocompatibility standards. The stainless steel needle ensures smooth, low-trauma puncture of infusion ports.
Luer lock connectors provide leak-proof attachment to catheters. You won't face connection failures during critical medication delivery.
EO sterilization renders the entire set non-pyrogenic and latex-free. Your patients with latex sensitivities are protected automatically.
| Parameter | Specification |
|---|---|
| Drop Factor | 60 drops/mL (micro-drip) |
| Tube Length | 150 cm |
| Air Vent | Without air vent (non-vented spike) |
| Tubing Material | Medical-grade PE/PP or DEHP-free PVC |
| Needle Type | High-quality stainless steel |
| Drip Chamber | Transparent, easy monitoring |
| Connector | Luer lock/Luer slip compatible |
| Sterilization Method | EO Gas Sterilized |
| Standards Compliance | ISO 8536-4, ISO 13485, CE certified |
| Pyrogen Status | Non-pyrogenic (LAL tested) |
| Latex Content | Latex-free |
| Minimum Order | 500,000 pieces |
| Lead Time | 30-45 days |
You face unique challenges when treating newborns and infants. Their small circulatory volumes make precise fluid management non-negotiable.
The product allows you to titrate maintenance fluids and medications with exceptional accuracy. Even at rates as low as 5-10 mL/hour, you can count drops reliably.
The extended tubing accommodates incubator setups without strain. Nurses can access the flow regulator without disturbing the infant's thermal environment.
Hazardous drug safety protocols require closed-system transfer devices. Our non-vented design complements your chemotherapy safety program perfectly.
You maintain system integrity from drug preparation through administration. The risk of drug exposure to healthcare workers drops significantly.
When administering vesicant agents, the consistent flow rate prevents accidental bolus delivery that could cause tissue extravasation.
ICU patients often require vasoactive drugs delivered at precise rates. While infusion pumps are standard, you need reliable backup options during equipment failure or patient transport.
This micro-drip set gives you manual control with pump-like precision. You can calculate exact drop rates and maintain hemodynamic stability even during ambulance transfers or when moving between departments.
The 60 Drops/mL IV Infusion Set without Air Vent, 150cm Tube becomes your failsafe when electronic systems aren't available or practical.
Our production facility operates under strict ISO 13485 quality management systems. Every batch undergoes rigorous testing before reaching your facility.
Drop factor accuracy testing ensures that 60 drops consistently equal 1.0 ml within certified tolerances. We perform statistical sampling on every production run.
Leakage testing under both positive and negative pressure confirms hermetic sealing at all connection points. You won't experience fluid leaks during clinical use.

Particulate contamination tests ensure no foreign matter enters the fluid pathway. We meet international limits for extractable substances and heavy metals.
Non-pyrogenicity testing using the LAL method guarantees the set won't trigger febrile reactions in your patients. This is especially critical for immunocompromised populations.
Tensile strength testing on the 150cm tubing validates that accidental pulling won't cause separation at joints. Your infusions remain secure during patient movement.
CE marking and FDA-recognized standards guide our production processes. You can confidently use our products in regulated healthcare markets worldwide.
Our 7 national patents demonstrate continuous innovation in medical device design. We don't just meet standards—we advance them.

HENAN AILE INDUSTRIAL CO., LTD has served healthcare institutions globally since 2014. Our commitment to quality, innovation, and customer support makes us your reliable partner in medical consumables.
With efficient production management and a stable supply chain, we deliver consistent products on schedule. Our 24-hour technical support team responds rapidly to your questions and service needs.
Whether you're a hospital procurement manager, medical distributor, or healthcare administrator, we provide the product that meets your clinical demands.

Q: What's the difference between vented and non-vented IV sets?
A: Non-vented sets like ours are designed for use with collapsible plastic infusion bags. The bag collapses as fluid empties, so no air vent is needed. Vented sets work with rigid glass bottles that require air displacement. You should choose non-vented sets for modern flexible containers to maintain a closed, sterile system.
Q: How do I calculate the infusion rate with a 60 drops/mL set?
A: The formula is: (Volume in mL × 60 drops/mL) ÷ (Time in minutes) = Drops per minute. For example, to infuse 50 mL over 1 hour: (50 × 60) ÷ 60 = 50 drops/minute. This micro-drip factor gives you finer control than standard 15 or 20 drops/mL sets.
Q: Can this set be used with infusion pumps?
A: Yes, the set is compatible with most gravity-fed and some peristaltic infusion pumps. However, its primary advantage is precise manual control. Always verify compatibility with your specific pump model before use.
Q: Is the 150cm tube length suitable for pediatric patients?
A: Absolutely. The extended length is actually advantageous in pediatric settings. It allows positioning of IV poles away from cribs and incubators, reducing the risk of accidental dislodgement. The excess tubing can be coiled neatly without kinking.
Q: What are the storage requirements?
A: Store in a cool, dry place away from direct sunlight. Avoid exposure to extreme temperatures that could affect material integrity. Check the expiration date on the package before use—our sets have a 5-year shelf life when stored properly.
Q: Do you offer OEM/ODM customization?
A: Yes, we welcome OEM and ODM partnerships. Our R&D team can customize specifications including tubing length, connector types, and packaging designs. Minimum order quantities apply for customized products.
Ready to enhance your IV therapy protocols with the 60 Drops/mL IV Infusion Set without Air Vent, 150cm Tube? Email us at admin@aileindus.com for product specifications, pricing, and delivery information.