Manufactured by Henan Aile Industrial Co., Ltd. (AVACARE), our Disposable Vacuum Blood Collection System Sterilized Tube Heparin Tube delivers rapid whole-blood anticoagulation and clean plasma separation for clinical biochemistry, emergency diagnostics, and blood rheology testing. Produced in our 12,000 m² standardized manufacturing facility operating Class 100,000 cleanrooms since 2014, each tube is manufactured from high-clarity medical-grade PET or borosilicate glass to prevent sample hemolysis, maintain negative vacuum stability, and ensure chemical neutrality. Supported by CE and ISO certifications, a standard 3-year shelf life, and flexible OEM/ODM capabilities, we supply international diagnostic laboratories, hospital networks, and medical distributors with dependable, high-yield diagnostic consumables.
Rapid Anticoagulation & Plasma Yield: Dosed with high-purity Sodium Heparin or Lithium Heparin to accelerate antithrombin III activation. This rapidly blocks the coagulation cascade without altering standard plasma biochemical analytes.
Uniform Ultrasonic Inner-Wall Spraying: Anticoagulant additive is micro-atomized evenly along the internal walls within Class 100,000 clean air zones, preventing micro-clotting and ensuring immediate sample homogenization.
Silanized Hemolysis-Resistant Surface: Advanced interior wall silanization prevents red blood cell adhesion, minimizes cellular damage, and ensures smooth specimen decanting during high-speed centrifugation.
Calibrated Vacuum Draw Accuracy: Computer-controlled negative-pressure evacuation ensures precise draw volume tolerances (±10%) across 3 ml to 10 ml specifications, maintaining proper blood-to-anticoagulant ratios.
Aerosol-Proof Green Safety Shield: The color-coded green safety cap encloses a self-sealing medical-grade butyl rubber stopper to prevent specimen aerosolization during decapping and eliminate leakage in pneumatic tube transit.
Certified Cleanroom Production: Fully fabricated, evacuated, assembled, and packed in Class 100,000 cleanrooms to guarantee validated sterility and non-pyrogenic interior purity.

| Parameter | Specification Details |
| Product Name |
Disposable Vacuum Blood Collection System Sterilized Tube Heparin Tube |
| Cap Color |
Green |
| Additive / Formulation |
Sodium Heparin / Lithium Heparin |
| Size / Draw Volume |
3 ml, 4 ml, 5 ml, 6 ml, 7 ml, 10 ml; |
| Tube Material |
Medical-Grade Polyethylene Terephthalate (PET) |
| Properties |
Medical Materials & Accessories |
| Instrument Classification |
Class II Medical Device |
| Quality Certification |
CE, ISO (ISO 13485 / CE Compliant)/ US FDA |
| Shelf Life |
3 Years |
| Centrifugation Speed |
2,500 – 3,000 × g for 10–15 minutes |
| Place of Origin |
China |
| Packaging Details |
100 pcs/Tray (Foam Rack), 12 Trays/Carton (1,200 pcs/ctn) |
| Lead Time |
30–45 Days |
STAT & Rapid Clinical Chemistry: Delivers interference-free plasma without waiting for whole-blood clotting, accelerating turnaround times for emergency electrolyte, renal, and cardiac enzyme profiles.
Blood Rheology & Hematocrit Testing: Preserves natural red blood cell morphology and suspension properties for clinical rheological evaluations.
Electrolyte & Trace Element Analysis: Lithium Heparin variants provide baseline-accurate electrolyte readings (including sodium and potassium) without introducing external metallic ion interference.
Automated Track & Analyzer Lines: Standardized 13 mm and 16 mm tube diameters fit automated clinical centrifuge buckets, barcode inspection tracks, and robotic decappers.

Venipuncture & Fill: Draw whole blood according to CLSI order-of-draw protocols until vacuum exhaustion completely draws the nominal target volume (3 ml – 10 ml).
Immediate Homogenization: Gently invert the tube 8 to 10 times immediately after collection to ensure thorough contact between the blood specimen and the heparin anticoagulant. (Note: Do not shake vigorously to avoid mechanical hemolysis.)
Centrifugation: Centrifuge at 2, 500 - 3, 000 X g for 10 to 15 minutes at room temperature to obtain pure, non-hemolyzed plasma supernatant for analyzer loading.
Direct Factory Production: Over a decade of specialized medical consumable fabrication eliminates trading markups, giving your distribution chain direct margin advantages.
High-Volume Supply Stability: Sustained manufacturing scale backed by Class 100,000 cleanrooms guarantees steady, uninterrupted deliveries for regional tenders.
Turnkey OEM/ODM Customization: Full customization capabilities for client private branding, target-language patient labels, and automated Code 128 or 2D DataMatrix barcodes.
Batch Lot Traceability: Every production run is issued with a standardized Certificate of Analysis (CoA) verifying draw accuracy, additive stability, and sterile enclosure.

Inner Packaging: 100 pieces per sealed foam rack/tray, vacuum shrink-wrapped to preserve cleanliness and cap alignment.
Master Shipper: 12 trays per export double-wall corrugated carton (1,200 pieces total).
Transit Protection: Reinforced moisture-barrier master cartons palletized to withstand ocean container freight and air cargo transport.
Storage Recommendations: Store upright between 4°C and 25°C in a dry, ventilated environment away from direct sunlight to preserve additive chemical stability and vacuum lifespan.

Q: When should Lithium Heparin be chosen over Sodium Heparin?
A: Lithium Heparin is the preferred standard for routine clinical chemistry and electrolyte determinations because it avoids elevating measured sodium levels. Sodium Heparin is typically selected for specific specialized diagnostic or research procedures where lithium could interfere with analyte detection.
Q: Can these tubes be processed immediately without a clotting rest period?
A: Yes. Because heparin acts directly as an anticoagulant rather than a clot activator, there is no need to wait 20–60 minutes for clot retraction. The sample can be centrifuged immediately after inversion mixing, making it ideal for STAT clinical emergency care.
Q: Do you support custom branding and barcode printing on the tube labels?
A: Yes, we provide full OEM/ODM services, including private branding, customized tear-resistant paper or plastic labels, client lot numbering, and pre-printed Code 128 or QR barcode formats.
Q: Are evaluation samples available prior to commercial bulk ordering?
A: Yes, evaluation sample packs across required volume capacities (3 ml to 10 ml) in PET or glass are provided upon request for automated laboratory validation and tender trials.

Ready to place an order or request technical data sheets for the Disposable Vacuum Blood Collection System Sterilized Tube Heparin Tube? Contact our international export department at admin@aileindus.com to confirm specifications, request samples, or schedule container shipments.